- Purpose
- Macro support for a beam position monitor. The BPM has a serial interface. This support uses the EPICS generic serial record as a communications channel.
- Dependencies
- These macros require:
- EPICS
- Experimental Physics and Industrial Control System, http://www.aps.anl.gov/epics
- EPICS support for XBPM
- The EPICS support for the X-ray Beam Position Monitor (XBPM) is needed to interface between the RS-232 connection on the XBPM and the EPICS IOC using an octal232 IP card. The software support consists of an EPICS generic serial record, an EPICS database, and a state notation language sequence program.
- EPICS PV support prefix
- The support prefix is
ioc:xbpm
(configurable inXBPM_PREFIX
)
Usage:
qdo /epics/clients/spec/macros/bpm.mac
-
GX_FACTOR
¶ constant declaration
X-axis calibration, mm/unit
-
GY_FACTOR
¶ constant declaration
Y-axis calibration, mm/unit
-
XBPM_PREFIX
¶ constant declaration
EPICS support prefix
-
BPM_read_diode
(u'chan',)
¶ def() macro function declaration
read current value from the named BPM channel
param character chan: channel letter (a, b, c, or d) example:
value = BPM_read_diode("b")
-
BPM_set_defaults
¶ def macro declaration
Set (or reset) proper default values on the XBPM.
Also, measure the dark signals at each amplifier gain scale (range) for each photodiode by calling
BPM_setAllDarkSignals
. This process takes about one minute. The software does not check to make sure that the beam is off so you should be sure that the shutter is closed during the time you run this macro. When finished, set the amplifier gain back to the value it had as this macro was started.
-
BPM_setDarkSignal
(u'range',)
¶ def() macro function declaration
measure and set the dark signal on each channel for the given amplifier range
param int range: \(0 <= range <= 5\) Measure and set the dark signal for each photodiode amplifier at the selected amplifier gain scale (range). Report the findings as a spec comment.
range gain 0 350 nA 1 700 nA 2 1400 nA 3 7 uA 4 70 uA 5 700 uA
-
BPM_setAllDarkSignals
¶ def macro declaration
measure and set the dark current for all amplifier ranges
Variable Declarations (bpm.mac)¶
objtype | name | start_line | summary |
---|---|---|---|
constant | GX_FACTOR | 30 | X-axis calibration, mm/unit |
constant | GY_FACTOR | 31 | Y-axis calibration, mm/unit |
constant | XBPM_PREFIX | 32 | EPICS support prefix |
Macro Declarations (bpm.mac)¶
objtype | name | start_line | end_line | summary |
---|---|---|---|---|
def | BPM_set_defaults | 48 | 92 | Set (or reset) proper default values on the XBPM. |
def | BPM_setAllDarkSignals | 153 | 161 | measure and set the dark current for all amplifier ranges |
Function Macro Declarations (bpm.mac)¶
objtype | name | start_line | end_line | args | summary |
---|---|---|---|---|---|
function def | BPM_read_diode | 34 | 46 | chan | read current value from the named BPM channel |
function def | BPM_setDarkSignal | 94 | 151 | range | measure and set the dark signal on each channel for the given amplifier range |